$NEWCAV group (optional) This group controls generation of the "escaped charge" cavity, used when ICOMP=3 or IREP=1 in $PCM. This cavity is used only to calculate the fraction of the solute electronic charge escapes from the original cavity. IPTYPE = choice for tessalation of the cavity's spheres. = 1 uses a tetrahedron = 2 uses a pentakisdodecahedron (default) ITSNUM = m, the number of tessera to use on each sphere. if IPTYPE=1, input m=30*(n**2), with n=1,2,3 or 4 if IPTYPE=2, input m=60*(n**2), with n=1,2,3 or 4 (default is 60) *** the next three parameters pertain to IREP=1 *** RHOW = density, relative to liquid water (default = 1.0) PM = molecular weight (default = 18.0) NEVAL = number of valence electrons on solute (default=8) The defaults for RHOW, PM, and NEVAL correspond to water, and therefore must be correctly input for other solvents. ========================================================== ==========================================================
generated on 7/7/2017